Mazda 323

since 1985 release

Repair and operation of the car



Mazda 323

+ Introduction
+ Petrol engines
+ Engine lubrication system
+ Engine cooling system
+ System of ignition
+ Power supply system, carburetor, system of injection of fuel
+ Diesel engine
+ System of production of the fulfilled gases
+ Coupling
+ Manual transmission
+ Automatic transmission
+ Suspension bracket and system of steering
+ Brake system
+ Wheels and tires, body, coloring of the car, care of the car
- System of electric equipment
   Search of malfunctions of electric system
   Check of the switch on a current transmission
   Check of the relay
   Check of the motor of a screen wiper
   Verification of indexes of turn
   Check of stoplights
   Check of a heater of back glass
   Separation and connection of cable plugs
   Arrangement of safety locks
   Replacement of safety locks
   Removal and installation of the battery
   Check of the battery
   The battery is discharged in itself
   Battery charging
   Storage of the battery
   Generator
   Security measures for the generator of alternating current
   Check of tension of the generator
   Removal and installation of the generator
   Generator components
   Dismantling generator/replacement of coal brushes
   Removal and installation of a starter
   Check/replacement of the traction relay of a starter
+ Heater, system of lighting, devices
+ Governing bodies and methods of operation
+ Electric circuits


25215d41

Check of a heater of back glass

 PERFORMANCE ORDER

  1. At the included heater of back glass the field with visible conductors has to be freed from rainfall or ice after a while.
  2. At malfunction at first to check a safety lock in a box of safety locks.
  3. If the safety lock is serviceable, to check durability of landing of the plug at the left and on the right on back glass, if necessary to clear of corrosion.
  4. If the heater does not work, to check wires to the switch, see the Head Sistem of electric equipment.
  5. To check operation of the switching relay, see the Section Check of the Relay.
  1. If the conductor of a heater has break, will help out a standard silvery conducting varnish. For this purpose to clear the field of repair by a thinner or ethylene.
  1. To glue the place of break on both sides an adhesive tape and to apply with a thin brush silvery paint.
  2. To allow paint to dry 24 hours at a temperature of +25 °C. It is also possible to use the hair dryer with hot air. At a temperature of +150 °C paint dries 30 minutes.

Not to include a heater of back glass, paint will not dry yet. Not to apply gasoline or other solvents to cleaning.