- At the included heater of back glass the field with visible conductors has to be freed from rainfall or ice after a while.
- At malfunction at first to check a safety lock in a box of safety locks.
- If the safety lock is serviceable, to check durability of landing of the plug at the left and on the right on back glass, if necessary to clear of corrosion.
- If the heater does not work, to check wires to the switch, see the Head Sistem of electric equipment.
- To check operation of the switching relay, see the Section Check of the Relay.
|
|
- If the conductor of a heater has break, will help out a standard silvery conducting varnish. For this purpose to clear the field of repair by a thinner or ethylene.
|
- To glue the place of break on both sides an adhesive tape and to apply with a thin brush silvery paint.
- To allow paint to dry 24 hours at a temperature of +25 °C. It is also possible to use the hair dryer with hot air. At a temperature of +150 °C paint dries 30 minutes.
|
|
Not to include a heater of back glass, paint will not dry yet. Not to apply gasoline or other solvents to cleaning. |
|
|