- For separation of cable connections on a box of safety locks or electric consumers it is necessary to pull not for a cable, and for the plug.
|
|
Plugs are equipped with various clamps. To press clamps in the places designated by shooters and at the same time to disconnect the plug. |
|
|
- At connection to squeeze the socket, the clamp will not be latched yet.
|
|
|
- During the checking of course of current or voltage measurement test probes can be inserted only from a reverse side of the plug (from a cable). If probes are inserted into nests of the socket, nests are deformed that will lead to weakening of contact.
|
|
|
In case of waterproof sockets (in a motive compartment) probes should not be inserted from a cable. In this case to separate the socket. To watch that at insertion of the probe of the plug were not damaged. |
|
|
- When replacing the plug in the plug to insert from the open party the narrow screw-driver between tightening uvulas and the plug. To wring out a uvula up and to take out the plug back. To insert the new plug until it is latched. To pull for a cable to be convinced that the plug is reliably fixed.
|
|
|